METPOINT FLM

Sensor technology for volume flow measurement

Every third compressor is only operated to compensate for air losses. These costs are largely avoidable. One possibility to avoid these costs is precise acquisition of the current volume flow. This then provides the basis for many important analyses, documentation and decisions. BEKO TECHNOLOGIES provides end-position monitoring with the METPOINTFLM SF13 and SF53

Function

Two temperature sensors are installed in series in the direction of flow. The first temperature sensor measures the current process temperature of the compressed air, while the second sensor is electrically heated to a temperature that is 40 K higher than that of the first sensor. Higher volume flows results in a quicker drop in temperature at the sensors, so that the electric heater of the second sensor must increase its heat output. The electric energy required to maintain the temperature difference is proportional to the volume flow. This energy consumption is converted to provide the relevant flow measurements